BRAND | Integra Metering AG (formerly Aquametro) |
Product | 92018 - VZO 40 RC 130/16-RV1 |
Description | CONTOIL® fuel oil meter With Reed pulser |
Internal code | IMP4868993 |
Technical specification | Impulse value 1 Measuring principle: Ring piston Nominal pressure: PN 16 bar Installation length: 300 mm Nominal diameter: DN 40 mm Threaded connection: 2" Couplings for pipe: 1-1/2" Installation position: horizontal/ vertical pipe Max. flow rate (Qmax): 9'000 l/h Max. continuous flow rate (Qcont): 6'000 l/h Min. flow rate (Qmin): 225 l/h Max. temperature: 130°C Registration capacity: 10'000'000 l Impulse value: 1 l Min. readable amount: 0.1 l With RV Reed pulse, max. 48 V AC/DC, 50 mA, 2 W Max. deviation: ± 1 % of value Repeatability: ± 0.2 % |
Please Contact Us to Order to offer competitive prices and delivery time for Integra Metering AG (formerly Aquametro) - 92018 - VZO 40 RC 130/16-RV1 CONTOIL® fuel oil meter With Reed pulser number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Serbia Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
PMWF-basic 32 10._150_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 150 mm Mounting position: vertical falling Pipe meter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.1 m³ / h Permanent flow Q3: 10 m³ / h Maximum flow Q4: 12.5 m³ / h Kvs-value: 10.3 m³ / h Pressure loss in Q3: 900 mbar Measuring range: R 100 Inlet section: 0 x DN 32 Outlet flow: 0 x DN 32 Degree of protection: IP 66 Approval MI-001
PMW-basic 16._300_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Thread connection: G 1 " Nominal size: DN 40 Mounting length: 300 mm Mounting position: horizontal Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.16 m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 25.6 m³ / h Pressure loss in Q3: 400 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001
PMWS-basic 16._200_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Connection thread: G 2 " Nominal size: DN 40 Mounting length: 200 mm Mounting position: vertical ascending Riser counter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0,16m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 20.8 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001
PMWF-basic 16._200_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Connection thread: G 2 " Nominal size: DN 40 Mounting length: 200 mm Mounting position: vertical falling Pipe meter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0,16m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 22.2 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001
CE test water meter R49 DN15-32
CE test water meter R49 DN40-50
ART.NO. 80113/2008 AQUAPULS 1L
System module aquapuls® For retrofitting aquabasic® cold water meters. Pulse value 1 l / pulse with return compensation. Switching capacity 220 mA / 48 VDC. Degree of protection IP 68 with 1.5 m cable, fixed. With battery power
DOMINO ® ARD structure group - Reguliergetriebe - Roller 6 digits, with RV Reed pulser, 48 VAC / DC, 50 mA, 2 W Specifications: Recording capacity Roller: 107 l Smallest readable Quantity: 0.1 l Pulse Value: 1 l
ART.NO. 92042 VZO 15 RC 130/16-RV0,1
Fuel Oil Meter
ART.NO. 92048 VZO 20 RC 130/16-RV1
CONTOIL® oil meter VZO 20 RC 130/16-RV 1 Ring piston meter for mineral oil, with rotatable roller counter
P/N 92280 Aquametro Oil Meter
VZO 25 FL 180 / EXP 10-20K
[CONTOIL ® fuel oil meters Reed pulser Pulse value 1.25 ml Nominal width: 4 mm With internal thread copper pipe: 1/8 " Nominal pressure: PN 25 Maximum permissible temperature: 50 ° C Mounting position: horizontal / vertical Largest flow Qmax. 80 l / h In continuous operation: 50 l / h Error of measurement: 1-80 l / h + / - 1% of the measurement error Recording capacity Roller 100 000 liters With built-on Reed pulser RE max:. 48V AC / DC, max. 50 mA, max. 3 VA Pulse value: 0.00125 l]
vzo-4 fuel counter
MOTOR AC230V 50/60HZ DN25 WITH CAPACITOR AND GEAR FOR ACTUATOR TYPE: 2KN:
fuel counter gear
fuel counter gear
(92042, CONTOIL® oil meter Reed pulser Pulse value 0.1 l, nominal width: 15 mm DN With 3/4 "thread for fittings: 1/2" Overall length: 165 mm Nominal pressure: PN 16 bar Max. Permissible temperature: 130 ° C Mounting position: horizontal / vertical Largest flow Qmax .: 600 l / h In continuous operation Qn .: 400 l / h Minimum flow rate Qmin .: 10 l / h Bias: 10-600 l / h ± 1% of reading Repeatability equal / better than 0.2% Total amount on roller 1 000 000 l Smallest readable Quantity: 0.01 l Pulser Reed, max.48 V AC / DC, 50 mA, 2 W Pulse value: 0.1 l Measuring principle: piston ring)
Oil meter with roller Measuring accuracy ± 1% Medium temperature to 130 ° C Roller counter with pulse generator, optionally Reed (RV) or Namur (IN) VZO 15 ... 50 with Flange EN 1092-1, PN 25
fuel meter
94606 PMWF-basic 32 10._150_1 1/4"
TOPAS hot water meter, Nominal Size: DN 32,With thread 1 1/2 "(for screw 1 1/4"),Nominal pressure: PN 16 bar,Overall length: 150 mm,Mounting position: vertical falling,Temperature max .: 90 ° C,Overload flow Q4: 12.5 m3 / h,Permanent flow rate Q3: 10 m3 / h,Transition flow Q2: 12:16 m3 / h,Minimum flow rate Q1: 0.1 m3 / h,Measuring range: R 100,Smallest readable amount: 0.1 l,Registrable: 100000 m3,Measuring principle: multi-jet turbine, dry running
81152 VSR 32 1 1/4" OR Klinger Sil
pair fittings
CE test hydr. Encoder EN1434 DN15-32
89206 TOPAS PMW 32-RH1 obsolete, replaced by 94249 and 96158
level indicator
92503 PMK-basic 15 2.5_165_1/2"
aquabasic® Kaltwasserzähler
96166 CE-Prüfung Wasserzähler R49 DN15-32
96166 CE-Prüfung Wasserzähler R49 DN15-32
Oil meter with roller meter
Flow meters for chemical liquids